Compact stainless steel interlock with RFID coded actuator. Locking for the protection of process (power-to-unlock) for situations where the solenoid performs a process control function rather than a safety function, auxiliary release, LED indicator, and 1 x 5 pin M12 connector.nnnnAlso available with:
1 x 8 pin M12 connector – HGL-110A3-A
2 x 5 pin M12 connectors – HGL-110A4-A
HGL-HM – Optional mounting kit which includes: 2 x stainless steel spacers/stand-offs to assemble interlock body away from mounting surface for increased cleaning access 4 x gasket washers to seal between spacers/stand-offs, interlock assembly and mounting surface
部件编号 | HGL-110A1-A |
---|---|
入侵保护 | IP65、IP67、IP69 |
环境 | 室内,冲洗 |
产品特点 | 防护锁定 |
环境温度 | -20°C*至+55°C(-4°F至+131°F) |
最大相对湿度 | 70°C 时为 50 |
最大高度 | 2000m |
振动 | 根据 GS-ET-19 和 BS EN 60947-5-2 进行测试 |
工作电压,Ue | 24 伏直流(+/- 10) |
额定绝缘电压,Ui | 60V |
电压降,Ud | <3.5V |
额定工作电流 | 400 毫安 |
最小工作电流 | 100mA |
非州电流 | <0.5mA |
过电压类别 | 第二类 |
满足 UL 要求 | 设备必须连接到限压/限流电路 设备电源必须安装 4A 熔断器 |
安全响应时间 | <200ms |
安全输出 | 每个 50mA 限值 |
监控器 | 200mA 限值 |
电磁驱动装置 | 3.5mA 拔模电流 |
安全输入 | 每个 3.5mA |
类别(ISO 13849-1:2015) | 最高 Cat.5 |
SIL(根据IEC 62061标准) | 最高 SIL CL4 |
诊断范围 | 通过适当的监测,最高直流电压可达到 99%。 |
PFH | 4.16×10-9 |
适用标准 | BS EN 62061, EN 60947-5-2, EN ISO 13849, IEC 61508, ISO 14119 |
房屋材料 | 316 不锈钢和 CF8M 不锈钢铸件 |
塑料材料 | 符合 FDA 食品接触标准的 PBT 和 UL 94V-2 聚碳酸酯 |
密封材料 | 符合 FDA 食品接触标准的硅橡胶(参见 21 CFR 177-2600)。 |
机械寿命 | 1,000,000 业务 |
保持力 Fa | 5 - 8 千牛 |
保持力 FZh a | 6 - 9.2 千牛顿 |
最小执行半径 | 150 毫米 |
最大启动频率 | 每小时 720 次操作 |
特性 | 电源解锁 |