TS-CLIN-024PU-60-600

A time delay device is used where machines do not come to an immediate stop. It controls keys giving access to enclosed areas or machines where hazards may be present, until a safe condition has been achieved.
Read More…
Part Number
TS-CLIN-024PU-60-600

Description

This time delay device features:

  • 1 Normally In Lock (key trapped)
  • Integrated isolated switch
  • CLIN – standard lock, no dustcover
  • 024 – 24v DC solenoid
  • PU – power-to-unlock
  • 60-600 – adjustable timer delay (1-10 minutes)
  • IP66 stainless steel enclosure

 Time delay devices from Fortress Safety are available in a variety of configurations, including:

  • Standard or master lock type
  • Standard or padlockable dustcover
  • Voltage type (24v, 110v, 230v)

Key(s) with engravings purchased separately

Additional Information

Additional information

Part Number

TS-CLIN-024PU-60-600

Housing Materials

IP66 Eldon stainless steel enclosure

Lock Mechanism

Die-cast zinc body with stainless operating mechanism

Ingress Protection

IP67

Minimum Operating Current

5mA at 20v

Power Consumption

24V DC = 16W, 110V AC = 63VA, 240V AC = 132VA

Switch Contact Rating

300V – 20A

Delay-on De-energisation

Approx. 40ms, Recovery Time 80ms

Environment

Indoor

Ambient Temperature

80% at ≤31°C 50% at 40°C

Standards

EN60947-3:2009 EN1088:1996 EN13849-1:2008 EN13849-2:2012 EN62061:2005

Certifications

CE marked for all applicable directives

Category

Cat. 4, PLe (EN / ISO 13849-1) and SIL3 (EN/IEC 62061)

Functional Safety Data - B10d

5,000,000

Functional Safety Data - DC

High 99% (with correct monitoring)

Features

Power-to-Unlock

Configure Another Part

Configure a different part number for this range or others to have an product which exactly meets your needs.

Datasheet drawing generator

Download drawings and CAD models of this specific part number using our product generator. Our configurators automatically create these in real time so this can take around 10 – 30 minutes to become available.

more products

THCGNSSELETSRP2W4
THHSNABSMDUEDP6P7P2Q8
THCP3PRP3EIQ8
THHGNQBBF
THHRXSMDU2AQ5
THFSMELQ5

Not sure where to start?

Contact our team of experts to discuss which solutions would work best for you applications, or use our custom configurators to build the right solution for you.

© Fortress Interlocks 2021. All rights reserved.

Log In to MyFortress

Don’t have an account yet?

© Fortress Interlocks 2024. All rights reserved.

Login to MyFortress

Don’t have an account yet?

© Fortress Interlocks 2021. All rights reserved.

Upcoming Webinar:

TS-CLIN-024PU-60-600