Each tGard stack has between one and ten slots for different elements which create an interlock that is configured for your specific application. Each slot can have a mix of different things, this page gives technical details about Solenoid Lock & Safety Switches.

If you are not familiar with tGard we recommend you first read about the range in general on the tGard product page or look at our how to buy tGard page to understand the process of configuring the perfect stack.

Solenoid Lock & Safety Switches

TSMDU, TSMEU, TSMFU, TSSEU

 

Power to Unlock 

 

Power to Unlock

 

Override key provided with power to unlock units.

 

 

Shown in a 4 way case

TSMDL, TSMEL, TSMFL, TSSEL

 

Power to Lock 

 

Power to Lock

 

 

 

 

Shown in a 4 way case

 

 

Solenoid Lock & Safety Switches

 

• TSS or TSM element incorporated to give dual safety circuits monitoring the door (or key) as well as 1 x N/O contact output (TSM only) for door monitoring (high when door open) and status LED. (Green when door closed, TSM only).
• 1 input used to energise solenoid.
• Power to Lock and Power to Unlock options available.

 

3 options for solenoid:

• TDU/L – Dual safety circuits wired in series with TSM dual safety circuits.
• TEU/L – No safety circuits for solenoid (solenoid monitor switch gives 24V on locked position)
• TFU/L – Dual safety circuits giving independent safety monitoring on solenoid in addition to TSS.

 

• 1 x N/O contact output for solenoid monitoring (high when unlocked) and status LED. (Red
when unlocked).
• Solenoid override key provided with power to unlock units.

 

Location

• First element after all mechanical elements (Head, Internal Release and Locks).

 

 

Operating Instructions

 

 

Back to tGard page

 

 

Technical Specifications of Solenoid Lock & Safety Switches

 

Housing Materials

Painted die cast aluminium

Colour

Dark Grey

Ingress Protection

IP65*

Retention Force Locked

2500N

Mechanical Life

1,000,000 Operations

Electrical Life

1,000,000 Operations

Maximum Frequency of Ops

1 per second

Ambient Temperature

-25°C to 40°C (-13°F to 104°F)

Environment

Indoor use only

Safety Switches

DC13: Le=0.5A, Ue=24V DC
AC15: Le=1A, Ue=24V AC

Monitoring Switches

DC13: Le=0.5A, Ue=24V DC

Solenoid Rating

350mA max @ 24VDC

Contact Material

Silver

*IP protection is to the tGard stack that this module attaches to, when correctly fitted according to installation and maintenance instructions.

Safety Switch

 

 

 

Safety Switch

 

TSM/TSP

 

 

 

Safety Switch

 

TSS

Safety Switch Element

Can be driven by either the operation of the head element (removal of actuator) or a mechanical lock.

 

• Operates on dual safety circuits.
• 2 positively driven force break NC contacts (uses none
of the Input/Output pins).
• IP65.
• 1 Normally Open (N/O) / monitoring contact giving 24V
signal on I/O pin (TSM only).
• Red LED illuminated to show door open (TSM & TSP).
• Extra retention force available (TSP).

 

Location

First element after all mechanical elements (Head,
Internal Release and Locks).

 

 

Operating Instructions

 

 

How to buy?

 

 

Technical Specifications

 

Housing Materials

Painted die cast aluminium

Colour

Dark Grey

Ingress Protection

IP65*

Mechanical Life

1,000,000 Operations

Retention Force

7 – 9N (TSS/TSM)
38 – 40N (TSP)

Maximum Frequency of Ops

1 per second

Ambient Temperature

-25°C to 40°C (-13°F to 104°F)

Environment

Indoor use only

Switching Principle

Positive Break

Switching Contact Element

2N/C on Safety Circuits
1 N/O per Monitor (TSM only)

Safety Switches

DC13: Le=0.5A, Ue=24V DC
AC15: Le=1A, Ue=24V AC

Monitoring Switches

DC13: Le=0.5A, Ue=24V DC

Voltage

24V DC

Contact Material

Silver

*IP protection is to the tGard stack that this module attaches to, when correctly fitted according to installation and maintenance instructions.

Safety Data 

 

Standards

EN13849-1
EN13849-2
EN14119

Approvals

TÜV SÜD for Europe, Canada & USA

Category

Cat. 3, PLd (EN/ISO 13849-1)
Note: EU and EL elements are only suitable for use above PLc when the equipment has no rundown time (i.e. the solenoid protects the process not people).

Functional Safety Data

B10d (for whole tGard device, which will contain multiple elements)/5,000,000

We are experts in providing safety solutions for automation

Contact us for tailor guidance and solutions for your machinery safety applications.