Each tGard stack has between one and ten slots for different elements which create an interlock that is configured for your specific application. Each slot can have a mix of different things, this page gives technical details about Quick Disconnects & Cables.
If you are not familiar with tGard we recommend you first read about the range in general on the tGard product page or look at our how to buy tGard page to understand the process of configuring the perfect stack.
Safety & Standard Control Connector
Safety & Standard Control Connector
- Safety Only, Control Only or Safety & Control.
- 5/8/12/14/19 pin depending on need.
- See Fortress Cables.
- Other configurations available on
request.
tGard Safety & Standard Control Connector Technical Specifications
Ingress Protection |
IP65* |
Ambient Temperature |
-25°C to 40°C (-13°F to 104°F) |
Environment |
Indoor use only |
Voltage |
24V DC |
Maximum current on power supply |
0.75A |
*IP protection is to the tGard device that this module attaches to, when correctly fitted according to installation and maintenance instructions.
Self Wire Connector
Self Wire Connector
- For applications where the customer wishes to make their own connections.
- Push fit terminals.
- Cable size 26-14 AWG.
- Available with 12 or 24 connections.
- Control only and Safety and Control versions available.
- M20 gland thread.
- Requires no additional mounting to frame.
- Self Wire Lid secured by x 4 screws (Screwdriver bit supplied).
tGard Self Wire Connector Technical Specifications
Housing Materials |
Painted die cast aluminium |
Colour |
Dark Grey |
Ambient Temperature |
-25°C to 40°C (-13°F to 104°F) |
Environment |
Indoor use only |
Ingress Protection |
IP65* |
Voltage |
24V DC |
Maximum current on power supply |
0.7A |
*IP protection is to the tGard stack that this module attaches to, when correctly fitted according to installation and maintenance instructions.
Foot – TBF
Foot
For terminating purely mechanical configurations (no wiring).
tGard Foot Technical Specifications
Housing Materials |
Painted die cast aluminium and black plastic |
Colour |
Dark Grey |
Ambient Temperature |
-25°C to 40°C (-13°F to 104°F) |
Environment |
Indoor use only |
Quick Disconnect Cables
Quick Disconnect Cables
- Range of Quick Disconnect Cables to suit the tGard range.
- Available in 2, 5, 10 &
20m.
Technical Specifications of Quick Disconnect Cables Base
Colour |
Light Grey & Dark Grey |
Ingress Protection |
IP65* |
Ambient Temperature |
-25°C to 40°C (-13°F to 104°F) |
Current |
200mA |
Voltage |
24V DC |
Seal |
Viton O-Ring |
Cable |
PUR |
Overmoulding |
PUR |
Environment |
Indoor use only |
*IP protection is to the tGard stack that this module attaches to, when correctly fitted according to installation and maintenance instructions.
We are experts in providing safety solutions for automation
Contact us for tailor guidance and solutions for your machinery safety applications