Compact interlock with RFID coded actuator. Locking for the protection of process (power-to-unlock) for situations where the solenoid performs a process control function rather than a safety function, auxiliary release, LED indicator, and 1 x 5 pin M12 connector. Also available with:
1 x 8 pin M12 connector – ATM-110A3-A
2 x 5 pin M12 connectors – ATM-110A4-A
Part Number | ATM-110A1-A |
---|---|
Ingress Protection | IP65, IP67 |
Environment | Indoor |
Ambient Temperature | -20°C * to +55°C (-4°F to +131°F) |
Maximum Relative Humidity | 50% at 70°C |
Maximum Altitude | 2000m |
Vibration | Tested in accordance with GS-ET-19 and BS 60947-5-2 |
Operating Voltage, Ue | 24V DC (+/- 10%) |
Rated Insulation Voltage, Ui | 60V |
Voltage Drop, Ud | <3.5V |
Rated Operating Currents | 400mA |
Minimum Operational Current | 100mA |
Off-State Current | <0.5mA |
Overvoltage Category | Type 2 |
To Meet UL Requirements | The device must be connected to a Limited Voltage/Current Circuit A 4A fuse must be fitted to the device power supply |
Safety Response Time | <200ms |
Safety Outputs | 50mA Limit Each |
Monitor | 200mA Limit |
Solenoid Drive | 3.5mA Draw |
Safety Inputs | 3.5mA Draw Each |
Category (ISO 13849-1:2015) | Up to Cat.4 |
SIL (according to IEC 62061) | Up to SIL CL3 |
Diagnostic Coverage | A maximum DC of 99% can be achieved with suitable monitoring. |
PFH | 4.16×10-9 |
Applicable Standards | 60947-5-2, BS 62061, IEC 61508, ISO 13849, ISO 14119 |
Features | Power-to-Unlock |
Receive expert insights, industry updates, and exclusive content straight to your inbox.
"*" indicates required fields
© Fortress Interlocks 2024. All rights reserved. Website crafted by isev
Stay ahead with the latest in safety solutions. Sign up for our newsletter to receive expert insights, industry updates, and exclusive content straight to your inbox.
"*" indicates required fields
Don’t have an account yet?